INSTALLATION AND OPERATOR’S MANUAL
12/02 LIT1011
244 Bergen Boulevard, West Paterson, NJ 07424 • Tel 9737854347 • Fax 9737853318 • Web www.fsrinc.com
Model ML - 800
8 ROOM AUDIO CONTROL SYSTEM
MONITOR VOLUME
MIN MAX
SALON VISALON I
SALON II SALON IV
SALON III
SALON V SALON VII
SALON VIII
MIX
C
MIX
A
MIX
D
MIX
B
MIX
E
MIX
F
MIX
G
MIX
J
MIX
H
MIX
K
MIX
I
. 5 4
ML-800
O 1 2 3 4 5 6 7 8
L
M
L
M
L
M
L
M
L
M
L
M
L
M
L
M
OFF
ROOM CONTROL SELECT AND STATUS INDICATORS
ROOM CONTROL
SPEECH AUDIO
MIXER
ROOM COMBINED
3
1
L
M
4
2
2
2
2
2
BACKGROUND MUSIC
LOCAL
VOLUME
VOLUME
ON/OFF ON/OFF
SOURCE
A B C D E F G H
I J K L M N O P
MIX SWITCH SELECT
SYSTEM MAP
PANEL
INTERLOCK
Vista de página 0
1 2 3 4 5 6 ... 43 44

Resumo do Conteúdo

Página 1 - Model ML - 800

INSTALLATION AND OPERATOR’S MANUAL12/02 LIT1011 244 Bergen Boulevard, West Paterson, NJ 07424 • Tel 9737854347 • Fax 9737853318 • Web www.fsrinc

Página 2

10 ML-800ML - 800 TOUCH WALLPLATE (optional)ML - 800 POWER SUPPLY PSA

Página 3 - Operators Safety Summary

ML-800 11EQUIPMENT PLACEMENTThe ML-800RACK is mounted first. It should go in the audio rack at eye level usually 55 inches fromthe finished

Página 4 - Contents

12 ML-800GROUNDINGIt is strongly recommended that in any rack setup to ensure appropriate power application aswell as superior power surg

Página 5 - CHAPTER ONE

ML - 800 112CHAPTER TWOWhat you will find in this chapter…• System Configuraton• System Block Diagram• System Components

Página 6 - INTRODUCTION

12 ML - 800ML-800 SYSTEM CONFIGURATIONThe ML-800 system allows the user greater flexibility than any other room combining system madetoday

Página 7 - UNPACKING

ML - 800 13A...There will be two types of wallplates available for use in the ML-800 system; membrane and LCD. Both controlall wallpl

Página 8 - ML-800 SYSTEM COMPONENTS

14 ML - 800OVERALL VIEW OF SYSTEM COMPONENTS MAP/MONITOR PANEL MAP/Monitor Panel OperationThe MAP/Monitor Panel acts as a master control po

Página 9 - ML-800 9

ML - 800 15ML - 800 TOUCH WALLPLATE (optional)

Página 10 - 10 ML-800

16 ML - 800ML-800 WALLPLATE (optional) 2 Gang (also available in 3 gang)MEMBRANE TYPE

Página 11 - EQUIPMENT PLACEMENT

ML - 800 17This is the main unit of the system. It routes the selected music, adjusts levels, combines rooms, handlescommunication (between

Página 12 - GROUNDING

2 ML-800PROPRIETARY INFORMATIONAll information in this manual is proprietary to and the property of FSR inc.This publication is

Página 13 - CHAPTER TWO

ML - 800 213CHAPTER THREEWhat you will find in this chapter…• System Specifications• Audio Connector Wiring• Cabling• Dip Switch / Jumper S

Página 14 - ML-800 SYSTEM CONFIGURATION

22 ML - 800SYSTEM SPECIFICATIONSAudioFrequency Response: 20 Hz – 20 kHz +/- .5 dBTHD: .03% @ 1kHz with MAX Rated Input LevelMAX Input level

Página 15 - ML - 800 SYSTEM BLOCK DIAGRAM

ML - 800 23Wall Plates MembraneSize: 6 1/4 inches wide by 4 1/2 inches high, approximately 2.5 inches deepMounting: fits standard 2 or 3

Página 16 - MIX SWITCH SELECT

24 ML - 800R-MON Remote Monitor Panel (optional)Size: 20" wide, 5 1/4" high, 2 1/8" deepMounting: standard rack railsPower:

Página 18 - MEMBRANE TYPE

ML - 800 25SOURCEOUTPUTDEVICE Input Wiring (single wire with overal shield)AUDIO CONNECTOR WIRINGIn any professional s

Página 19

26 ML - 800CABLINGAUDIOAll audio connections to the ACU are 3 pin connectors with pin 1 shield, pin 2 High, and pin 3 Low.CONTROL WIRINGThe

Página 20 - CHAPTER THREE

ML - 800 27WALLPLATESThe wallplates can be wired in either a home run (star) or modified daisy chain configuration.Use two twisted pair 22

Página 21 - SYSTEM SPECIFICATIONS

28 ML - 800ACU Audio Control Unit, CPU ModuleThe CPU PC board contains sixteen (16) dip switches which will allow users to customize the s

Página 22

ML - 800 29Dip switch 5 and 6 - Wallplate Interlock Mode.If Switch 5 is closed, the wallplate keyswitch has no effect on the operation of t

Página 23

ML-800 3Operators Safety SummaryThe general safety information in this summary is for operating personnel.Do Not Remove Covers or PanelsThe

Página 24

30 ML - 800WALLPLATES (optional)The wallplates used in the ML-800 system are either membrane or touch. They control all wallplatefunctions.

Página 25 - AUDIO CONNECTOR WIRING

ML - 800 31Membrane Wallplate Dip Switch SettingsThe ML-800 allows for up to 16 wallplates: 2 per room up to 8 rooms. The wallplates must b

Página 26

32 ML - 800 Wall Plate Functions All wallplates will handle these functions in the same way.Speech/AudioAlternating action switch that enab

Página 27 - (THIS IS ONE PAIR)

ML - 800 33ADJUSTMENTSAs with any high performance audio system, proper adjustment is key to achieving optimum S/N (signal to noise) ratio

Página 28 - DIP SWITCH / JUMPER SETTINGS

34 ML - 800At this point, the entire system is calibrated, with the exception of the power amplifier gain setting. Toset the power amplifie

Página 29

ML - 800 354CHAPTER FOURWhat you will find in this chapter…• Paging Operation• Facility Manager Operation

Página 30

36 ML - 800The Room Combining System supports the integration of a new or existing paging system. APage Audio input, and Normal/Priority mo

Página 31 - SWITCH POSITIONS

ML - 800 37FACILITY MANAGERS PANELThe Facility Managers Panel (FMP) is a Windows based program that performs all the same functions as the

Página 32

38 ML - 800Group FunctionsThe FMP group functions include defining groups, adding rooms to groups, and removing groups. These functions ar

Página 33 - ADJUSTMENTS

ML - 800 395CHAPTER FIVEWhat you will find in this chapter…• Multiple ACU's• Remote Map and Monitor Panels• Audio / Lighting Systems

Página 34

4 ML-800ContentsCHAPTER ONE ...

Página 35 - CHAPTER FOUR

40 ML - 800MULTIPLE ACUsIn order to control more than 16 rooms the Room Combining System has the ability to create groupsthat overlap ACUs.

Página 36 - PAGING SYSTEM OPERATION

ML - 800 41Diagram illustrating multiple ACUsML-800 RACK #1ML-800 RACK #2To wallmount transformer(supplied)HOST COMPUTER

Página 37 - FACILITY MANAGERS PANEL

42 ML - 800REMOTE MAP AND MONITOR PANELSR-MAP and R-MONITORThis accessory permits full operation of the Room Combining System from a locati

Página 38 - 38 ML - 800

ML - 800 43Now it is possible to have the lighting follow the audio output Mix Lamp Status from the ML-800room combining system. The additi

Página 39 - CHAPTER FIVE

44 ML - 800The electrical contractor shall be responsible for the mounting of the ‘GRX-AV’ or ‘FSR-CIP’interface and wiring to the lighting

Página 40 - MULTIPLE ACUs

ML-800 51CHAPTER ONEWhat you will find in this chapter…• Introduction• Unpacking Data• System Components• Equipment Placement• Grounding Co

Página 41 - HOST COMPUTER

6 ML-800INTRODUCTIONThe design of the ML-800 system takes advantage of current technology to provide a blend of reliability,ease of use,

Página 42 - REMOTE MAP AND MONITOR PANELS

ML-800 7UNPACKINGYour ML-800 system should contain the following components;• ML-800RACK (audio control unit) This is the rack unit with t

Página 43 - INSTALLATION

8 ML-800ML-800 SYSTEM COMPONENTSML-800RACKpage control inputP=priorityN=normalG=groundREAR VIEWto FM INT for computercontrol via FM-Panel

Página 44 - Control signals outputs

ML-800 9ML-800 WALLPLATE (optional) 2 Gang shown (also available in 3 gang)MEMBRANE TYPE

Comentários a estes Manuais